Arbitrary notifications via spoofed node identity
Published Sep 3, 2026 · Updated Sep 5, 2026
Source-identity spoofing in MOOS-IvP uFldNodeComms 24.8.1 and earlier allows remote attackers to post arbitrary variable notifications. FldNodeComms::handleMailNodeMessage() trusts src_node from each NODE_MESSAGE body, so range, staleness, and group checks use the claimed node's ledger entry before uFldMessageHandler posts the named variable without an allowlist. Any field publisher that can reach the MOOSDB path can impersonate another node and alter mission-control variables, including deploy, return, abort, or manual-override state.
Summary
What happened
Source-identity spoofing in MOOS-IvP uFldNodeComms 24.8.1 and earlier allows remote attackers to post arbitrary variable notifications. FldNodeComms::handleMailNodeMessage() trusts src_node from each NODE_MESSAGE body, so range, staleness, and group checks use the claimed node's ledger entry before uFldMessageHandler posts the named variable without an allowlist. Any field publisher that can reach the MOOSDB path can impersonate another node and alter mission-control variables, including deploy, return, abort, or manual-override state.
The record
- CVE
- CVE-2026-85429
- Published
- Sep 3, 2026
- Updated
- Sep 5, 2026
- Vendor
- MOOS-IvP
- Product
- MOOS-IvP
- Classifications
- CWE-345, T1565.002
- Attack vector
- network
- Privileges
- unauthenticated
Timeline
How it unfolded
- Sep 3, 2026CVE publishedPublication date reported by the CVE source.
- Sep 5, 2026Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=0 <=24.8.1
What conditions does exploitation require?
What is affected?
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- Spoofed NODE_MESSAGE validation caseproof of concept · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.