CVE-2026-64934Network attack vector

Update suppression via unverified firmware reports

Published Aug 11, 2026 · Updated Aug 11, 2026

Security decision bypass in Mira Android App 4.5.15.4 and Mira Hormone Monitor Firmware 1.7.1.47 allows remote authenticated users to falsify status. The Mira cloud API treats a firmware-version string supplied by the companion app as authoritative without independently attesting the version on the paired monitor. Control of an authenticated account and its device is required; forged reports can suppress update prompts and distort vulnerable-fleet and patch-adoption records.

CVSS severity5.3
Medium
EPSS probability0.21%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Security decision bypass in Mira Android App 4.5.15.4 and Mira Hormone Monitor Firmware 1.7.1.47 allows remote authenticated users to falsify status. The Mira cloud API treats a firmware-version string supplied by the companion app as authoritative without independently attesting the version on the paired monitor. Control of an authenticated account and its device is required; forged reports can suppress update prompts and distort vulnerable-fleet and patch-adoption records.

The record

CVE
CVE-2026-64934
Published
Aug 11, 2026
Updated
Aug 11, 2026
Vendor
Quanovate Tech Inc.
Product
Mira Hormone Monitor Firmware
Classifications
CWE-807, T1565.002
Attack vector
network
Privileges
authenticated

Timeline

How it unfolded

  1. Aug 11, 2026CVE publishedPublication date reported by the CVE source.
  2. Aug 11, 2026Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=1.7.1.47

What conditions does exploitation require?

Attack vectornetwork
Required privilegesauthenticated

What is affected?

Quanovate Tech Inc. · Mira Hormone Monitor Firmwareversion=1.7.1.47
Quanovate Tech Inc. · Mira Android Appversion=4.5.15.4

Published CVSS scores

4.3CISACVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
5.3CISA-ADPCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-807Reliance on Untrusted Inputs in a Security Decision
T1565.002Transmitted Data Manipulation

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo