CVE-2026-3556

Remote code execution via Pair-Setup heap overflow

Published Mar 13, 2026 · Updated Mar 13, 2026

Heap-based buffer overflow in Philips Hue Bridge 1.73.1973146020 allows remote attackers to execute code through HomeKit Pair-Setup. The hk_hap_pair_storage_put function copies attacker-controlled data into a fixed-length heap buffer without first validating its length. An unauthenticated attacker on the same local network can run code in the HomeKit service context, gaining the service's access to the Bridge.

CVSS severity8.8
High
EPSS probability0.51%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Heap-based buffer overflow in Philips Hue Bridge 1.73.1973146020 allows remote attackers to execute code through HomeKit Pair-Setup. The hk_hap_pair_storage_put function copies attacker-controlled data into a fixed-length heap buffer without first validating its length. An unauthenticated attacker on the same local network can run code in the HomeKit service context, gaining the service's access to the Bridge.

The record

CVE
CVE-2026-3556
Published
Mar 13, 2026
Updated
Mar 13, 2026
Vendor
Signify
Product
Philips Hue Bridge
Classifications
CWE-122, T1210
Attack vector
adjacent
Privileges
unauthenticated

Timeline

How it unfolded

  1. Mar 13, 2026CVE publishedPublication date reported by the CVE source.
  2. Mar 13, 2026Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=1.73.1973146020

What conditions does exploitation require?

Attack vectoradjacent
Required privilegesunauthenticated

What is affected?

Signify · Philips Hue Bridgeversion=1.73.1973146020

Published CVSS scores

8.8Zero Day InitiativeCVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectoradjacent
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-122Heap-based Buffer Overflow
T1210Exploitation of Remote Services

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.