Code injection in Schneider Electric EcoStruxure Automation Expert before 25.0.1 allows local users to run commands via a malicious project file. Schneider Electric has not disclosed which project-file parser or operation converts attacker-controlled project content into executable commands. Exploitation requires an authenticated user to open the file on a Windows engineering workstation, enabling compromise of that workstation and subsequent systems.

CVSS severity7.2
High
EPSS probability0.23%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Code injection in Schneider Electric EcoStruxure Automation Expert before 25.0.1 allows local users to run commands via a malicious project file. Schneider Electric has not disclosed which project-file parser or operation converts attacker-controlled project content into executable commands. Exploitation requires an authenticated user to open the file on a Windows engineering workstation, enabling compromise of that workstation and subsequent systems.

The record

CVE
CVE-2026-2273
Published
Mar 10, 2026
Updated
Mar 10, 2026
Vendor
Distributed Data Systems
Product
EcoStruxure Automation Expert
Classifications
CWE-94, T1204.002
Attack vector
local
Privileges
authenticated

Timeline

How it unfolded

  1. Mar 10, 2026CVE publishedPublication date reported by the CVE source.
  2. Mar 10, 2026Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=Versions prior to v25.0.1

What conditions does exploitation require?

Attack vectorlocal
Required privilegesauthenticated

What is affected?

Distributed Data Systems · EcoStruxure Automation Expertversion=Versions prior to v25.0.1

Published CVSS scores

8.2Schneider Electric SECVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H
7.2Schneider Electric SECVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:L/VI:H/VA:L/SC:H/SI:H/SA:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorlocal
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-94Improper Control of Generation of Code ('Code Injection')
T1204.002Malicious File

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo