Authenticated command execution via unchecked sysCmd parameter
Published May 31, 2026 · Updated May 31, 2026
Command injection in TRENDnet TEW-432BRP 3.10B20 allows remote authenticated users to execute operating system commands. The boa binary's formSysCmd handler passes the HTTP POST sysCmd value from /goform/formSysCmd directly to the router's operating system without validating its contents. Valid web-management credentials and network access to the interface are required; submitted commands run on the appliance, and the published proof of concept reboots it.
Summary
What happened
Command injection in TRENDnet TEW-432BRP 3.10B20 allows remote authenticated users to execute operating system commands. The boa binary's formSysCmd handler passes the HTTP POST sysCmd value from /goform/formSysCmd directly to the router's operating system without validating its contents. Valid web-management credentials and network access to the interface are required; submitted commands run on the appliance, and the published proof of concept reboots it.
The record
- CVE
- CVE-2026-10180
- Published
- May 31, 2026
- Updated
- May 31, 2026
- Vendor
- TRENDnet
- Product
- TEW-432BRP
- Classifications
- CWE-77, CWE-74, T1059
- Attack vector
- network
- Privileges
- authenticated
Timeline
How it unfolded
- May 31, 2026CVE publishedPublication date reported by the CVE source.
- May 31, 2026Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=3.10B20
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- TEW-432BRP formSysCmd reboot proof of conceptproof of concept · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.
Technologies
Your stack
See the directory against your own environment.
Your stack
Check the software in your environment
Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.