Authenticated code execution via unchecked SSID copy
Published Aug 10, 2025 · Updated Aug 12, 2025
Stack overflow in Linksys RE6250, RE6300, RE6350, RE6500, RE7000, and RE9000 20250801 allows remote authenticated users to execute code. The wirelessBasic handler stores submit_SSID1 with nvram_bufset and later copies it into a stack-local buffer without a length check, allowing the return address to be overwritten. A valid session cookie and network access to /goform/wirelessBasic are required; successful exploitation grants code execution, while the published request demonstrates a device-service crash.
Summary
What happened
Stack overflow in Linksys RE6250, RE6300, RE6350, RE6500, RE7000, and RE9000 20250801 allows remote authenticated users to execute code. The wirelessBasic handler stores submit_SSID1 with nvram_bufset and later copies it into a stack-local buffer without a length check, allowing the return address to be overwritten. A valid session cookie and network access to /goform/wirelessBasic are required; successful exploitation grants code execution, while the published request demonstrates a device-service crash.
The record
- CVE
- CVE-2025-8820
- Published
- Aug 10, 2025
- Updated
- Aug 12, 2025
- Vendor
- Linksys
- Product
- RE6250
- Classifications
- CWE-121, CWE-119, T1210
- Attack vector
- network
- Privileges
- authenticated
Timeline
How it unfolded
- Aug 10, 2025CVE publishedPublication date reported by the CVE source.
- Aug 12, 2025Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=20250801
What conditions does exploitation require?
What is affected?
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- Linksys wirelessBasic submit_SSID1 HTTP proof of conceptproof of concept · demonstrated