CVE-2025-54926Network attack vector

Administrator code execution via path-traversal upload

Published Aug 20, 2025 · Updated Aug 20, 2025

Path traversal in Schneider Electric EcoStruxure Power Monitoring Expert allows remote authenticated users to execute code via an HTTP upload. The upload workflow accepts an administrator-supplied malicious file without restricting its path to the intended directory, after which the server executes it. Affected releases include PME 2022, 2023, 2024, and 2024 R2 and Power Operation 2022 and 2024 with Advanced Reporting; administrator privileges are required.

CVSS severity7.2
High
EPSS probability0.91%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Path traversal in Schneider Electric EcoStruxure Power Monitoring Expert allows remote authenticated users to execute code via an HTTP upload. The upload workflow accepts an administrator-supplied malicious file without restricting its path to the intended directory, after which the server executes it. Affected releases include PME 2022, 2023, 2024, and 2024 R2 and Power Operation 2022 and 2024 with Advanced Reporting; administrator privileges are required.

The record

CVE
CVE-2025-54926
Published
Aug 20, 2025
Updated
Aug 20, 2025
Vendor
Distributed Data Systems
Product
EcoStruxure Power Monitoring Expert
Classifications
CWE-22, T1190
Attack vector
network
Privileges
admin

Timeline

How it unfolded

  1. Aug 20, 2025CVE publishedPublication date reported by the CVE source.
  2. Aug 20, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=Version 2022
  2. Affected versionversion=Version 2023
  3. Affected versionversion=Version 2024
  4. Affected versionversion=Version 2024 R2

What conditions does exploitation require?

Attack vectornetwork
Required privilegesadmin

What is affected?

Distributed Data Systems · EcoStruxure Power Monitoring Expertversion=Version 2022; version=Version 2023; version=Version 2024; version=Version 2024 R2
Distributed Data Systems · EcoStruxure Power Operation - Advanced Reporting and Dashboards Moduleversion=Version 2022 w/ Advanced Reporting Module; version=Version 2024 w/ Advanced Reporting Module

Published CVSS scores

7.2Schneider ElectricCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesadmin
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-22Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
T1190Exploit Public-Facing Application

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo