Physical root access via unauthenticated UART console
Published Sep 9, 2025 · Updated Sep 12, 2025
Improper privilege management in seven Calix GigaCenter ONT models allows physically proximate attackers to gain root access via UART. The Broadcom SoC debugging console accepts a 115200-baud serial connection and opens a full root shell without requesting credentials. Physical access, device disassembly, and a USB-to-UART adapter are required; affected models are 812G, 813G, 818G, 844E, 844G, 844GE, and 854GE.
Summary
What happened
Improper privilege management in seven Calix GigaCenter ONT models allows physically proximate attackers to gain root access via UART. The Broadcom SoC debugging console accepts a 115200-baud serial connection and opens a full root shell without requesting credentials. Physical access, device disassembly, and a USB-to-UART adapter are required; affected models are 812G, 813G, 818G, 844E, 844G, 844GE, and 854GE.
The record
- CVE
- CVE-2025-53914
- Published
- Sep 9, 2025
- Updated
- Sep 12, 2025
- Vendor
- Calix
- Product
- GigaCenter ONT
- Classifications
- CWE-269, CAPEC-122, T1200
- Attack vector
- physical
- Privileges
- unauthenticated
Timeline
How it unfolded
- Sep 9, 2025CVE publishedPublication date reported by the CVE source.
- Sep 12, 2025Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=812G
- Affected versionversion=813G
- Affected versionversion=818G
- Affected versionversion=844E
- Affected versionversion=844G
- Affected versionversion=844GE
- Affected versionversion=854GE
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- Broadcom SoC UART root-shell procedurefunctional · demonstrated