CVE-2025-3705

Full device control via malicious USB configuration

Published Jul 7, 2025 · Updated Jul 7, 2025

OS command injection in Frauscher FDS101, FDS-SNMP101, and FDS102 allows physically proximate attackers to gain full device control. The configuration loader passes unneutralized special elements from a malicious configuration file into an operating-system command when reading it from a USB drive. Physical access to an affected railway diagnostic appliance and insertion of the crafted USB drive are required; successful execution permits arbitrary commands with control of the device.

CVSS severity6.8
Medium
EPSS probability0.78%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

OS command injection in Frauscher FDS101, FDS-SNMP101, and FDS102 allows physically proximate attackers to gain full device control. The configuration loader passes unneutralized special elements from a malicious configuration file into an operating-system command when reading it from a USB drive. Physical access to an affected railway diagnostic appliance and insertion of the crafted USB drive are required; successful execution permits arbitrary commands with control of the device.

The record

CVE
CVE-2025-3705
Published
Jul 7, 2025
Updated
Jul 7, 2025
Vendor
Frauscher Sensortechnik GmbH
Product
Frauscher Diagnostic System FDS101
Classifications
CWE-78, T1200
Attack vector
physical
Privileges
unauthenticated

Timeline

How it unfolded

  1. Jul 7, 2025CVE publishedPublication date reported by the CVE source.
  2. Jul 7, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0.0.0 <=v1.4.25

What conditions does exploitation require?

Attack vectorphysical
Required privilegesunauthenticated

What is affected?

Frauscher Sensortechnik GmbH · Frauscher Diagnostic System FDS101version=0.0.0 <=v1.4.25
Frauscher Sensortechnik GmbH · Frauscher Diagnostic System FDS-SNMP101version=0.0.0 <=v.2.3.9
Frauscher Sensortechnik GmbH · Frauscher Diagnostic System FDS102version=0.0.0 <v2.13.3

Published CVSS scores

6.8CERT@VDECVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorphysical
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-78Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
T1200Hardware Additions

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.