Reachable assertion in Siemens SIMATIC RTLS Locating Manager before 3.3 allows local users to interrupt service via loopback input. The listener on the local loopback interface insufficiently validates received data, allowing crafted input to trigger an assertion that interrupts the affected process. No product authentication or user interaction is required, but the attacker must send traffic from the host to the loopback-only port.

CVSS severity6.9
Medium
EPSS probability0.13%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Reachable assertion in Siemens SIMATIC RTLS Locating Manager before 3.3 allows local users to interrupt service via loopback input. The listener on the local loopback interface insufficiently validates received data, allowing crafted input to trigger an assertion that interrupts the affected process. No product authentication or user interaction is required, but the attacker must send traffic from the host to the loopback-only port.

The record

CVE
CVE-2025-30034
Published
Aug 12, 2025
Updated
Aug 12, 2025
Vendor
Siemens
Product
SIMATIC RTLS Locating Manager
Classifications
CWE-617, T0814
Attack vector
local
Privileges
unauthenticated

Timeline

How it unfolded

  1. Aug 12, 2025CVE publishedPublication date reported by the CVE source.
  2. Aug 12, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <V3.3

What conditions does exploitation require?

Attack vectorlocal
Required privilegesunauthenticated

What is affected?

Siemens · SIMATIC RTLS Locating Managerversion=0 <V3.3

Published CVSS scores

5.5NIST NVDCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.2Siemens ProductCERTCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.9Siemens ProductCERTCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorlocal
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-617Reachable Assertion
T0814Denial of Service

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo