CVE-2025-2995Public exploitNetwork attack vector

Unauthenticated password change via crafted HTTP request

Published Mar 31, 2025 · Updated Mar 31, 2025

Improper access control in the Tenda FH1202 1.2.0.14(408) web interface allows remote attackers to change device passwords. The SysToolChangePwd handler accepts a crafted unauthenticated HTTP POST request at the goform endpoint and applies password settings without enforcing access control. No prior session is required, and the resulting credential change can deny legitimate administrative access to the router.

CVSS severity6.9
Medium
EPSS probability0.83%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Improper access control in the Tenda FH1202 1.2.0.14(408) web interface allows remote attackers to change device passwords. The SysToolChangePwd handler accepts a crafted unauthenticated HTTP POST request at the goform endpoint and applies password settings without enforcing access control. No prior session is required, and the resulting credential change can deny legitimate administrative access to the router.

The record

CVE
CVE-2025-2995
Published
Mar 31, 2025
Updated
Mar 31, 2025
Vendor
Shenzhen Tenda Technology Co., Ltd.
Product
FH1202
Classifications
CWE-284, CWE-266, T1098
Attack vector
network
Privileges
unauthenticated

Timeline

How it unfolded

  1. Mar 31, 2025CVE publishedPublication date reported by the CVE source.
  2. Mar 31, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=1.2.0.14(408)

What conditions does exploitation require?

Attack vectornetwork
Required privilegesunauthenticated

What is affected?

Shenzhen Tenda Technology Co., Ltd. · FH1202version=1.2.0.14(408)

Published CVSS scores

5.3VulDBCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
5.0VulDBAV:N/AC:L/Au:N/C:N/I:P/A:N
6.9VulDBCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitPublished

Weakness, pattern, technique

CWE-284Improper Access Control
CWE-266Incorrect Privilege Assignment
T1098Account Manipulation

Public exploit references

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo