Authenticated code execution via unchecked parameter copy
Published Dec 30, 2025 · Updated Dec 30, 2025
Stack-based buffer overflow in Tenda M3 1.0.0.13(4903) allows remote authenticated users to execute code via a crafted POST request. The formSetAdPushInfo handler in /bin/httpd copies the mac or terminal parameter with memcpy() without bounds checking, corrupting its stack buffer. Low-privileged credentials and network access to /goform/setAdPushInfo are required; exploitation can hijack control flow or crash the controller.
Summary
What happened
Stack-based buffer overflow in Tenda M3 1.0.0.13(4903) allows remote authenticated users to execute code via a crafted POST request. The formSetAdPushInfo handler in /bin/httpd copies the mac or terminal parameter with memcpy() without bounds checking, corrupting its stack buffer. Low-privileged credentials and network access to /goform/setAdPushInfo are required; exploitation can hijack control flow or crash the controller.
The record
- CVE
- CVE-2025-15232
- Published
- Dec 30, 2025
- Updated
- Dec 30, 2025
- Vendor
- Shenzhen Tenda Technology Co., Ltd.
- Product
- M3 Access Controller
- Classifications
- CWE-119, CWE-121, T1190
- Attack vector
- network
- Privileges
- authenticated
Timeline
How it unfolded
- Dec 30, 2025CVE publishedPublication date reported by the CVE source.
- Dec 30, 2025Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=1.0.0.13(4903)
What conditions does exploitation require?
What is affected?
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- Tenda M3 setAdPushInfo Buffer Overflow PoCproof of concept · unverified