CVE-2025-13779

Unauthenticated configuration disclosure via improper session validation

Published Mar 13, 2026 · Updated Mar 13, 2026

Missing authentication in ABB AWIN GW100 rev.2 2.0-0 and 2.0-1 and AWIN GW120 1.2-0 and 1.2-1 allows remote attackers to read configuration data. The embedded web server accepts an unauthenticated query because session validation does not properly enforce authentication, exposing system configuration and sensitive details. Exploitation requires adjacent-network access to a gateway behind the site firewall; no user interaction or prior account is required.

CVSS severity7.2
High
EPSS probability0.29%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Missing authentication in ABB AWIN GW100 rev.2 2.0-0 and 2.0-1 and AWIN GW120 1.2-0 and 1.2-1 allows remote attackers to read configuration data. The embedded web server accepts an unauthenticated query because session validation does not properly enforce authentication, exposing system configuration and sensitive details. Exploitation requires adjacent-network access to a gateway behind the site firewall; no user interaction or prior account is required.

The record

CVE
CVE-2025-13779
Published
Mar 13, 2026
Updated
Mar 13, 2026
Vendor
GENEREX SYSTEMS Computervertriebsgesellschaft mbH
Product
AWIN GW100 WirelessHART Gateway rev.2
Classifications
CWE-306
Attack vector
adjacent
Privileges
unauthenticated

Timeline

How it unfolded

  1. Mar 13, 2026CVE publishedPublication date reported by the CVE source.
  2. Mar 13, 2026Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=2.0-0
  2. Affected versionversion=2.0-1

What conditions does exploitation require?

Attack vectoradjacent
Required privilegesunauthenticated

What is affected?

GENEREX SYSTEMS Computervertriebsgesellschaft mbH · AWIN GW100 WirelessHART Gateway rev.2version=2.0-0; version=2.0-1
GENEREX SYSTEMS Computervertriebsgesellschaft mbH · AWIN GW120 WirelessHART Gatewayversion=1.2-0; version=1.2-1

Published CVSS scores

8.1ABBCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H/E:F/RL:U/RC:C
7.2ABBCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N
8.3ABBCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectoradjacent
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-306Missing Authentication for Critical Function

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.