CVE-2025-1055Public exploit

Privileged process termination via unauthorized driver IOCTL

Published Jun 10, 2025 · Updated Jun 11, 2025

Missing authorization in K7 Computing K7 Security Anti-Malware before 23.0.0.10 allows local users to terminate privileged processes via IOCTLs. The K7RKScan.sys IOCTL handler accepts a caller-supplied process identifier without checking caller authorization, then invokes kernel process termination. Low-privilege local access is sufficient; successful requests can stop administrative or system services and applications, but operating-system-protected processes remain exempt.

CVSS severity5.6
Medium
EPSS probability0.22%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Missing authorization in K7 Computing K7 Security Anti-Malware before 23.0.0.10 allows local users to terminate privileged processes via IOCTLs. The K7RKScan.sys IOCTL handler accepts a caller-supplied process identifier without checking caller authorization, then invokes kernel process termination. Low-privilege local access is sufficient; successful requests can stop administrative or system services and applications, but operating-system-protected processes remain exempt.

The record

CVE
CVE-2025-1055
Published
Jun 10, 2025
Updated
Jun 11, 2025
Vendor
K7 Computing
Product
K7 Security Anti-Malware
Classifications
CWE-862, CAPEC-122, T1489
Attack vector
local
Privileges
authenticated

Timeline

How it unfolded

  1. Jun 10, 2025CVE publishedPublication date reported by the CVE source.
  2. Jun 11, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <23.0.0.10

What conditions does exploitation require?

Attack vectorlocal
Required privilegesauthenticated

What is affected?

K7 Computing · K7 Security Anti-Malwareversion=0 <23.0.0.10

Published CVSS scores

5.6PentrazeCVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:N/I:N/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorlocal
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitPublished

Weakness, pattern, technique

CWE-862Missing Authorization
CAPEC-122Privilege Abuse
T1489Service Stop

Public exploit references

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo