Stored script execution via unencoded renderer properties
Published Sep 10, 2025 · Updated Sep 10, 2025
Stored cross-site scripting in Scada-LTS 2.7.8.0 and 2.7.8.1 allows remote authenticated users to execute script in another user's browser. The Data Point Edit page stores crafted Text Renderer property content and returns it in generated HTML without neutralizing executable markup. Administrative access is required to alter the data point, and exploitation requires another user to view the stored content in the Scada-LTS origin.
Summary
What happened
Stored cross-site scripting in Scada-LTS 2.7.8.0 and 2.7.8.1 allows remote authenticated users to execute script in another user's browser. The Data Point Edit page stores crafted Text Renderer property content and returns it in generated HTML without neutralizing executable markup. Administrative access is required to alter the data point, and exploitation requires another user to view the stored content in the Scada-LTS origin.
The record
- CVE
- CVE-2025-10234
- Published
- Sep 10, 2025
- Updated
- Sep 10, 2025
- Vendor
- Abil'I.T.
- Product
- Scada-LTS
- Classifications
- CWE-79, T1189
- Attack vector
- network
- Privileges
- admin
Timeline
How it unfolded
- Sep 10, 2025CVE publishedPublication date reported by the CVE source.
- Sep 10, 2025Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=2.7.8.0
- Affected versionversion=2.7.8.1
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- Stored XSS in Scada-LTS Data Point Editproof of concept · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.
Technologies
Your stack
See the directory against your own environment.
Your stack
Check the software in your environment
Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.