CVE-2024-9579

Command execution via unsanitized firmware input

Published Nov 5, 2024 · Updated Nov 5, 2024

Command injection in affected Poly conferencing-device firmware allows remote attackers on the adjacent network to execute commands. HP states only that the firmware fails to sanitize user input and does not disclose the input field, endpoint, command-building locus, or shell invocation involved. Exploitation requires a high-complexity layered attack and cannot use this flaw alone; successful command execution can compromise device confidentiality, integrity, and availability.

CVSS severity7.5
High
EPSS probability0.40%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Command injection in affected Poly conferencing-device firmware allows remote attackers on the adjacent network to execute commands. HP states only that the firmware fails to sanitize user input and does not disclose the input field, endpoint, command-building locus, or shell invocation involved. Exploitation requires a high-complexity layered attack and cannot use this flaw alone; successful command execution can compromise device confidentiality, integrity, and availability.

The record

CVE
CVE-2024-9579
Published
Nov 5, 2024
Updated
Nov 5, 2024
Vendor
Polycom
Product
Poly TC10 Firmware
Classifications
CWE-77, T1059
Attack vector
adjacent
Privileges
unauthenticated

Timeline

How it unfolded

  1. Nov 5, 2024CVE publishedPublication date reported by the CVE source.
  2. Nov 5, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <6.3.2

What conditions does exploitation require?

Attack vectoradjacent
Required privilegesunauthenticated

What is affected?

Polycom · Poly TC10 Firmwareversion=0 <6.3.2
Polycom · Poly G7500 Firmwareversion=0 <4.3.2
Polycom · Poly Studio X70 Firmwareversion=0 <4.3.2
Polycom · Poly TC8 Firmwareversion=0 <6.3.2
Polycom · Poly Studio G62 Firmwareversion=0 <4.3.2
Polycom · Poly Studio X52 Firmwareversion=0 <4.3.2
Polycom · Poly Studio X50 Firmwareversion=0 <4.3.2
Polycom · Poly Studio X30 Firmwareversion=0 <4.3.2

Published CVSS scores

7.5NIST NVDCVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
7.5HP Inc.CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectoradjacent
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')
T1059Command and Scripting Interpreter

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo