CVE-2024-7448

Code execution via unsanitized acquisition string

Published Aug 21, 2024 · Updated Sep 3, 2024

Command injection in Magnet Forensics AXIOM 8.0.0.39753 allows attackers to execute code via a malicious mobile device. The Android device image acquisition functionality passes an inadequately validated device-supplied string to a system call. Exploitation requires an examiner to acquire data from the malicious device, and injected code runs with the examiner's user privileges.

CVSS severity8.0
High
EPSS probability1.71%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Command injection in Magnet Forensics AXIOM 8.0.0.39753 allows attackers to execute code via a malicious mobile device. The Android device image acquisition functionality passes an inadequately validated device-supplied string to a system call. Exploitation requires an examiner to acquire data from the malicious device, and injected code runs with the examiner's user privileges.

The record

CVE
CVE-2024-7448
Published
Aug 21, 2024
Updated
Sep 3, 2024
Vendor
Magnet Forensics
Product
Magnet AXIOM
Classifications
CWE-78, T1204
Attack vector
adjacent
Privileges
unauthenticated

Timeline

How it unfolded

  1. Aug 21, 2024CVE publishedPublication date reported by the CVE source.
  2. Sep 3, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=8.0.0.39753

What conditions does exploitation require?

Attack vectoradjacent
Required privilegesunauthenticated

What is affected?

Magnet Forensics · Magnet AXIOMversion=8.0.0.39753

Published CVSS scores

8.0Zero Day InitiativeCVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 9, 2026Sep 15, 2026
Latest reporting daySep 15, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectoradjacent
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-78Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
T1204User Execution

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo