Authenticated command execution via unsanitized template parameter
Published Jul 26, 2024 · Updated Aug 1, 2024
OS command injection in Raisecom MSG1200, MSG2100E, MSG2200, and MSG2300 3.90 allows remote authenticated users to execute commands. The /vpn/list_base_config.php endpoint fails to neutralize shell metacharacters in the template parameter before using it in a system command. The CNA requires low privileges, although honeypot traffic reached the endpoint without authentication; successful requests download and run arbitrary binaries.
Summary
What happened
OS command injection in Raisecom MSG1200, MSG2100E, MSG2200, and MSG2300 3.90 allows remote authenticated users to execute commands. The /vpn/list_base_config.php endpoint fails to neutralize shell metacharacters in the template parameter before using it in a system command. The CNA requires low privileges, although honeypot traffic reached the endpoint without authentication; successful requests download and run arbitrary binaries.
The record
- CVE
- CVE-2024-7120
- Published
- Jul 26, 2024
- Updated
- Aug 1, 2024
- Vendor
- Raisecom Technology Co., Ltd.
- Product
- MSG1200
- Classifications
- CWE-78, T1190, T1059.004
- Attack vector
- network
- Privileges
- authenticated
Timeline
How it unfolded
- Jul 26, 2024CVE publishedPublication date reported by the CVE source.
- Aug 1, 2024Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=3.90
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- Command Injection Vulnerability in RAISECOM Gateway Devicesfunctional · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.
Reported exploitation
Technologies
Your stack
See the directory against your own environment.
Your stack
Check the software in your environment
Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.
Book a demo