Authenticated service interruption via read-only access control
Published Nov 12, 2024 · Updated Nov 12, 2024
Improper access control in Siemens SCALANCE M-800 and RUGGEDCOM RM1224 firmware before 8.2 allows remote authenticated users to interrupt service. The device access-control handling permits read-only users to reach an operation that can trigger temporary denial of service, but Siemens has not disclosed the operation or request involved. A valid read-only account and network access to the management interface are required, and the documented consequence is a temporary service interruption without data disclosure or modification.
Summary
What happened
Improper access control in Siemens SCALANCE M-800 and RUGGEDCOM RM1224 firmware before 8.2 allows remote authenticated users to interrupt service. The device access-control handling permits read-only users to reach an operation that can trigger temporary denial of service, but Siemens has not disclosed the operation or request involved. A valid read-only account and network access to the management interface are required, and the documented consequence is a temporary service interruption without data disclosure or modification.
The record
- CVE
- CVE-2024-50558
- Published
- Nov 12, 2024
- Updated
- Nov 12, 2024
- Vendor
- Siemens
- Product
- SCALANCE MUM856-1 (RoW)
- Classifications
- CWE-284, T1499
- Attack vector
- network
- Privileges
- authenticated
Timeline
How it unfolded
- Nov 12, 2024CVE publishedPublication date reported by the CVE source.
- Nov 12, 2024Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=0 <V8.2
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Public exploit references
No public exploit references are available in this record.
Labels summarize the accepted research assessment. They do not indicate a test against your environment.
Technologies
Your stack
See the directory against your own environment.
Your stack
Check the software in your environment
Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.
Book a demo