Stored XSS in Plantronics Poly Clariti Manager 10.10.2.2 and earlier allows remote authenticated users to execute script over adjacent networks. HP has not disclosed the affected input field or page, only that unneutralized input is embedded during web-page generation. Low-privileged adjacent-network access is required, and injected script can read or modify data in the browser context where the stored content is rendered.

CVSS severity5.4
Medium
EPSS probability0.26%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Stored XSS in Plantronics Poly Clariti Manager 10.10.2.2 and earlier allows remote authenticated users to execute script over adjacent networks. HP has not disclosed the affected input field or page, only that unneutralized input is embedded during web-page generation. Low-privileged adjacent-network access is required, and injected script can read or modify data in the browser context where the stored content is rendered.

The record

CVE
CVE-2024-41911
Published
Aug 6, 2024
Updated
Oct 28, 2024
Vendor
Plantronics
Product
Poly Clariti Manager
Classifications
CWE-79, T1203
Attack vector
adjacent
Privileges
authenticated

Timeline

How it unfolded

  1. Aug 6, 2024CVE publishedPublication date reported by the CVE source.
  2. Oct 28, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=See HP Security Bulletin reference for affected versions.

What conditions does exploitation require?

Attack vectoradjacent
Required privilegesauthenticated

What is affected?

Plantronics · Poly Clariti Managerversion=See HP Security Bulletin reference for affected versions.

Published CVSS scores

5.4HP Inc.CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N
5.4NIST NVDCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
5.4CISA-ADPCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectoradjacent
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-79Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
T1203Exploitation for Client Execution

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo