Runtime crash via truncated response pointers
Published Sep 18, 2024 · Updated Nov 4, 2025
Invalid pointer dereference in OpenPLC Runtime v3 16bf8bac1a36d95b73e7b8722d0edb8b9c5bb56a allows remote attackers to crash via EtherNet/IP requests. Protected_Logical_Write_Reply truncates three response-field pointers to 32 bits before memmove dereferences them, producing invalid addresses on 64-bit systems. Repeated unauthenticated function-code 0xAA or 0xAB requests can terminate the PLC runtime and interrupt its control service without disclosing or modifying data.
Summary
What happened
Invalid pointer dereference in OpenPLC Runtime v3 16bf8bac1a36d95b73e7b8722d0edb8b9c5bb56a allows remote attackers to crash via EtherNet/IP requests. Protected_Logical_Write_Reply truncates three response-field pointers to 32 bits before memmove dereferences them, producing invalid addresses on 64-bit systems. Repeated unauthenticated function-code 0xAA or 0xAB requests can terminate the PLC runtime and interrupt its control service without disclosing or modifying data.
The record
- CVE
- CVE-2024-39590
- Published
- Sep 18, 2024
- Updated
- Nov 4, 2025
- Vendor
- OpenPLC Project
- Product
- OpenPLC Runtime v3
- Classifications
- CWE-704, T0814
- Attack vector
- network
- Privileges
- unauthenticated
Timeline
How it unfolded
- Sep 18, 2024CVE publishedPublication date reported by the CVE source.
- Nov 4, 2025Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=16bf8bac1a36d95b73e7b8722d0edb8b9c5bb56a
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Public exploit references
- Cisco Talos PCCC Protected Typed Logical Write demonstrationproof of concept · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.