CVE-2024-39567

System code execution via unsanitized VPN configuration

Published Jul 9, 2024 · Updated Aug 27, 2025

Command injection in Siemens SINEMA Remote Connect Client before 3.2 HF1 allows local users to execute code with system privileges. The client system service loads attacker-controlled VPN configuration values without server-side input sanitation before passing them to command execution. A locally authenticated account is required, and successful exploitation elevates that account's code execution to system privileges.

CVSS severity8.5
High
EPSS probability0.90%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Command injection in Siemens SINEMA Remote Connect Client before 3.2 HF1 allows local users to execute code with system privileges. The client system service loads attacker-controlled VPN configuration values without server-side input sanitation before passing them to command execution. A locally authenticated account is required, and successful exploitation elevates that account's code execution to system privileges.

The record

CVE
CVE-2024-39567
Published
Jul 9, 2024
Updated
Aug 27, 2025
Vendor
Siemens
Product
SINEMA Remote Connect Client
Classifications
CWE-77, T1068
Attack vector
local
Privileges
authenticated

Timeline

How it unfolded

  1. Jul 9, 2024CVE publishedPublication date reported by the CVE source.
  2. Aug 27, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <V3.2 HF1

What conditions does exploitation require?

Attack vectorlocal
Required privilegesauthenticated

What is affected?

Siemens · SINEMA Remote Connect Clientversion=0 <V3.2 HF1

Published CVSS scores

7.8Siemens AGCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.5Siemens AGCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorlocal
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')
T1068Exploitation for Privilege Escalation

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo