CVE-2024-3907Public exploitNetwork attack vector

Authenticated memory corruption via oversized funcpara1 input

Published Apr 17, 2024 · Updated Aug 1, 2024

Stack-based buffer overflow in Tenda AC500 2.0.1.9(1307) allows remote authenticated users to corrupt process memory through funcpara1. Public records identify the formSetCfm handler at /goform/setcfm and the oversized input, but the exact copying operation is undisclosed. The management interface requires authentication, and the resulting corruption can crash its service or subvert control flow.

CVSS severity9.8
Critical
EPSS probability1.91%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Stack-based buffer overflow in Tenda AC500 2.0.1.9(1307) allows remote authenticated users to corrupt process memory through funcpara1. Public records identify the formSetCfm handler at /goform/setcfm and the oversized input, but the exact copying operation is undisclosed. The management interface requires authentication, and the resulting corruption can crash its service or subvert control flow.

The record

CVE
CVE-2024-3907
Published
Apr 17, 2024
Updated
Aug 1, 2024
Vendor
Shenzhen Tenda Technology Co., Ltd.
Product
AC500
Classifications
CWE-787, CWE-121, T1210
Attack vector
network
Privileges
authenticated

Timeline

How it unfolded

  1. Apr 17, 2024CVE publishedPublication date reported by the CVE source.
  2. Aug 1, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=-2.0.1.9(1307)
  2. Affected versionversion=2.0.1.9(1307)

What conditions does exploitation require?

Attack vectornetwork
Required privilegesauthenticated

What is affected?

Shenzhen Tenda Technology Co., Ltd. · AC500version=-2.0.1.9(1307); version=2.0.1.9(1307)

Published CVSS scores

9.8NIST NVDCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8VulDBCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.0VulDBAV:N/AC:L/Au:S/C:C/I:C/A:C

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 9, 2026Sep 15, 2026
Latest reporting daySep 15, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitPublished

Weakness, pattern, technique

CWE-787Out-of-bounds Write
CWE-121Stack-based Buffer Overflow
T1210Exploitation of Remote Services

Public exploit references

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo