CVE-2024-33496

Local privilege escalation via exposed Report Client credentials

Published May 14, 2024 · Updated Aug 2, 2024

Credential exposure in Siemens SIMATIC RTLS Locating Manager Report Client before 3.0.1.1 allows local users to gain Systemadministrator access. The Report Client fails to protect credentials used for server authentication, but Siemens has not disclosed the storage location or protection failure. An authenticated Manager session and local host access are required; extracted credentials enable escalation to the Systemadministrator role.

CVSS severity6.3
Medium
EPSS probability0.15%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Credential exposure in Siemens SIMATIC RTLS Locating Manager Report Client before 3.0.1.1 allows local users to gain Systemadministrator access. The Report Client fails to protect credentials used for server authentication, but Siemens has not disclosed the storage location or protection failure. An authenticated Manager session and local host access are required; extracted credentials enable escalation to the Systemadministrator role.

The record

CVE
CVE-2024-33496
Published
May 14, 2024
Updated
Aug 2, 2024
Vendor
Siemens
Product
SIMATIC RTLS Locating Manager
Classifications
CWE-522, T1555
Attack vector
local
Privileges
authenticated

Timeline

How it unfolded

  1. May 14, 2024CVE publishedPublication date reported by the CVE source.
  2. Aug 2, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <3.0.1.1
  2. Affected versionversion=0 <V3.0.1.1

What conditions does exploitation require?

Attack vectorlocal
Required privilegesauthenticated

What is affected?

Siemens · SIMATIC RTLS Locating Managerversion=0 <3.0.1.1; version=0 <V3.0.1.1

Published CVSS scores

6.3Siemens AGCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L
4.8Siemens AGCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorlocal
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-522Insufficiently Protected Credentials
T1555Credentials from Password Stores

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo