CVE-2024-22041Network attack vector

Network-service crash via X.509 certificate parsing

Published Mar 12, 2024 · Updated Dec 16, 2025

Memory corruption in Siemens fire-protection products allows remote attackers to crash the network service with a crafted X.509 certificate. The shared network communication library mishandles memory buffers while parsing certificate data, causing the service process to terminate. Most products are reachable by unauthenticated attackers on the fire-system network; engineering tools and Sinteso Mobile require man-in-the-middle attackers, and impact is confined to the application.

CVSS severity7.5
High
EPSS probability0.51%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Memory corruption in Siemens fire-protection products allows remote attackers to crash the network service with a crafted X.509 certificate. The shared network communication library mishandles memory buffers while parsing certificate data, causing the service process to terminate. Most products are reachable by unauthenticated attackers on the fire-system network; engineering tools and Sinteso Mobile require man-in-the-middle attackers, and impact is confined to the application.

The record

CVE
CVE-2024-22041
Published
Mar 12, 2024
Updated
Dec 16, 2025
Vendor
Siemens
Product
Cerberus PRO UL X300 Cloud Distribution
Classifications
CWE-119, T0814, T1499.004
Attack vector
network
Privileges
unauthenticated

Timeline

How it unfolded

  1. Mar 12, 2024CVE publishedPublication date reported by the CVE source.
  2. Dec 16, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=*
  2. Affected versionversion=0 <V4.3.0001

What conditions does exploitation require?

Attack vectornetwork
Required privilegesunauthenticated

What is affected?

Siemens · Cerberus PRO UL X300 Cloud Distributionversion=*; version=0 <V4.3.0001
Siemens · Sinteso FS20 EN X300 Cloud Distribution MP8version=0 <V4.3.5617
Siemens · Cerberus PRO EN X200 Cloud Distribution IP8version=0 <V4.3.5618
Siemens · Sinteso FS20 EN Fire Panel FC20 MP6version=0 <*
Siemens · Cerberus PRO EN Fire Panel FC72xversion=-
Siemens · Desigo Fire Safety UL X300 Cloud Distributionversion=0 <V4.3.0001
Siemens · Cerberus PRO EN Fire Panel FC72x IP8version=0 <IP8 SR4
Siemens · Cerberus PRO EN Fire Panel FC72x IP6version=0 <*
Siemens · Sinteso FS20 EN X200 Cloud Distribution MP8version=0 <V4.3.5618
Siemens · Cerberus PRO EN X200 Cloud Distributionversion=-
Siemens · Desigo Fire Safety UL Engineering Toolversion=0 <MP4; version=0 <v4.3.0001
Siemens · Sinteso FS20 EN X200 Cloud Distributionversion=*
Siemens · Sinteso Mobileversion=*; version=0 <*
Siemens · Sinteso FS20 EN X300 Cloud Distributionversion=*
Siemens · Cerberus PRO EN X300 Cloud Distribution IP8version=0 <V4.3.5617
Siemens · Cerberus PRO UL Compact Panel FC922/924version=*; version=0 <MP4
Siemens · Cerberus PRO UL Engineering Toolversion=*; version=0 <MP4
Siemens · Sinteso FS20 EN X300 Cloud Distribution MP7version=0 <*
Siemens · Sinteso FS20 EN Fire Panel FC20 MP7version=0 <*
Siemens · Cerberus PRO EN X200 Cloud Distribution IP7version=0 <*
Siemens · Cerberus PRO EN X300 Cloud Distributionversion=-
Siemens · Sinteso FS20 EN Fire Panel FC20version=-
Siemens · Cerberus PRO EN Engineering Toolversion=-; version=0 <*
Siemens · Sinteso FS20 EN Engineering Toolversion=0 <*
Siemens · Cerberus PRO EN X300 Cloud Distribution IP7version=0 <*
Siemens · Cerberus PRO EN Fire Panel FC72x IP7version=0 <*
Siemens · Sinteso FS20 EN Fire Panel FC20 MP8version=0 <MP8 SR4
Siemens · Sinteso FS20 EN X200 Cloud Distribution MP7version=0 <*
Siemens · Desigo Fire Safety UL Compact Panel FC2025/2050version=0 <mp4; version=0 <MP4

Published CVSS scores

7.5Siemens ProductCERTCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
8.7Siemens ProductCERTCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-119Improper Restriction of Operations within the Bounds of a Memory Buffer
T0814Denial of Service
T1499.004Application or System Exploitation

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo