Code execution via malformed ICS file parsing
Published Dec 30, 2024 · Updated Dec 31, 2024
Out-of-bounds write in Delta Electronics DRASimuCAD 1.02 and earlier allows attackers to execute code via a crafted ICS file. The ICS parser does not validate user-supplied file data against the allocated buffer boundary, permitting a write past its end. Execution requires the target to open the file or visit a malicious page, and the resulting code runs in the current process context.
Summary
What happened
Out-of-bounds write in Delta Electronics DRASimuCAD 1.02 and earlier allows attackers to execute code via a crafted ICS file. The ICS parser does not validate user-supplied file data against the allocated buffer boundary, permitting a write past its end. Execution requires the target to open the file or visit a malicious page, and the resulting code runs in the current process context.
The record
- CVE
- CVE-2024-12835
- Published
- Dec 30, 2024
- Updated
- Dec 31, 2024
- Vendor
- Delta Electronics, Inc.
- Product
- DRASimuCAD
- Classifications
- CWE-787, T1203
- Attack vector
- local
- Privileges
- unauthenticated
Timeline
How it unfolded
- Dec 30, 2024CVE publishedPublication date reported by the CVE source.
- Dec 31, 2024Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=1.02
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Public exploit references
No public exploit references are available in this record.
Labels summarize the accepted research assessment. They do not indicate a test against your environment.
Technologies
Your stack
See the directory against your own environment.
Your stack
Check the software in your environment
Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.