CVE-2023-50811Network attack vector

Cross-reception control via mutable reception identifier

Published Mar 19, 2024 · Updated Mar 27, 2025

Incorrect authorization in SELESTA Visual Access Manager 4.38.6 allows remote authenticated users to control other reception stations. The application accepts a client-controlled computer POST parameter as a reception identifier without verifying the account's assigned reception. Low-privileged network access is required, and changing the identifier grants control of additional receptions without reported data disclosure or service interruption.

CVSS severity6.5
Medium
EPSS probability0.45%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Incorrect authorization in SELESTA Visual Access Manager 4.38.6 allows remote authenticated users to control other reception stations. The application accepts a client-controlled computer POST parameter as a reception identifier without verifying the account's assigned reception. Low-privileged network access is required, and changing the identifier grants control of additional receptions without reported data disclosure or service interruption.

The record

CVE
CVE-2023-50811
Published
Mar 19, 2024
Updated
Mar 27, 2025
Vendor
Unknown vendor
Product
Unknown product
Classifications
CWE-863, CWE-444, T1190
Attack vector
network
Privileges
authenticated

Timeline

How it unfolded

  1. Mar 19, 2024CVE publishedPublication date reported by the CVE source.
  2. Mar 27, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Affected buildAffected product and version details are unavailable.

What conditions does exploitation require?

Attack vectornetwork
Required privilegesauthenticated

What is affected?

Affected products and versions are unavailable in this record.

Published CVSS scores

6.5NIST NVDCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
6.5CISA-ADPCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 9, 2026Sep 15, 2026
Latest reporting daySep 15, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-863Incorrect Authorization
CWE-444Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling')
T1190Exploit Public-Facing Application

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.