CVE-2023-44321Network attack vector

Web management outage via unchecked input length

Published Nov 14, 2023 · Updated Feb 25, 2026

Uncontrolled resource consumption in Siemens SCALANCE devices before V4.6 or V8.1 allows remote authenticated users to interrupt web management. Configuration-change handlers in the web interface fail to validate input lengths before processing attacker-controlled field values. Administrative access is required, and successful exploitation leaves the web interface unavailable until the device is restarted.

CVSS severity2.7
Low
EPSS probability1.00%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Uncontrolled resource consumption in Siemens SCALANCE devices before V4.6 or V8.1 allows remote authenticated users to interrupt web management. Configuration-change handlers in the web interface fail to validate input lengths before processing attacker-controlled field values. Administrative access is required, and successful exploitation leaves the web interface unavailable until the device is restarted.

The record

CVE
CVE-2023-44321
Published
Nov 14, 2023
Updated
Feb 25, 2026
Vendor
Siemens
Product
SCALANCE XR328-4C WG (24xFE, 4xGE, DC24V)
Classifications
CWE-400, T1499
Attack vector
network
Privileges
admin

Timeline

How it unfolded

  1. Nov 14, 2023CVE publishedPublication date reported by the CVE source.
  2. Feb 25, 2026Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <V4.6

What conditions does exploitation require?

Attack vectornetwork
Required privilegesadmin

What is affected?

Siemens · SCALANCE XR328-4C WG (24xFE, 4xGE, DC24V)version=0 <V4.6
Siemens · SCALANCE XC208G (EIP def.)version=0 <V4.6
Siemens · SCALANCE XB213-3LD (SC, E/IP)version=0 <V4.6
Siemens · SCALANCE XC208G PoEversion=0 <V4.6
Siemens · SCALANCE XC208Gversion=0 <V4.6
Siemens · SCALANCE XR328-4C WG (24xFE, 4xGE, AC230V)version=0 <V4.6
Siemens · SCALANCE MUM856-1 (RoW)version=0 <V8.1
Siemens · SCALANCE XR324WGversion=0 <V4.6
Siemens · SCALANCE MUM856-1 (B1)version=0 <V8.1
Siemens · SCALANCE XC206-2 (ST/BFOC)version=0 <V4.6
Siemens · SCALANCE XC206-2SFP G (EIP DEF.)version=0 <V4.6
Siemens · SCALANCE XP208EECversion=0 <V4.6
Siemens · SCALANCE XC206-2SFP Gversion=0 <V4.6
Siemens · SCALANCE XP216Gversion=0 <V4.6
Siemens · SCALANCE MUM856-1 (EU)version=0 <V8.1
Siemens · SIPLUS NET SCALANCE XC208version=0 <V4.6
Siemens · SCALANCE XF204Gversion=0 <V4.6
Siemens · SCALANCE XC216-4C G (EIP Def.)version=0 <V4.6
Siemens · SCALANCE XB205-3 (ST, PN)version=0 <V4.6
Siemens · SCALANCE XP216 (Ethernet/IP)version=0 <V4.6
Siemens · SCALANCE XC224-4C G (EIP Def.)version=0 <V4.6
Siemens · SCALANCE XR328-4C WG (28xGE, DC 24V)version=0 <V4.6
Siemens · SCALANCE XB213-3LD (SC, PN)version=0 <V4.6
Siemens · RUGGEDCOM RM1224 LTE(4G) NAMversion=0 <V8.1
Siemens · RUGGEDCOM RM1224 LTE(4G) EUversion=0 <V8.1
Siemens · SCALANCE XC208G EECversion=0 <V4.6
Siemens · SCALANCE XF204-2BAversion=0 <V4.6
Siemens · SCALANCE XP216version=0 <V4.6
Siemens · SCALANCE M874-3version=0 <V8.1
Siemens · SCALANCE MUM856-1 (A1)version=0 <V8.1
Siemens · SCALANCE XC216-4Cversion=0 <V4.6
Siemens · SCALANCE XP208G PPversion=0 <V4.6
Siemens · SCALANCE XB206-2LDversion=0 <V4.6
Siemens · SCALANCE XC206-2SFPversion=0 <V4.6
Siemens · SCALANCE XF204 DNAversion=0 <V4.6
Siemens · SCALANCE XC216version=0 <V4.6
Siemens · SCALANCE MUM853-1 (B1)version=0 <V8.1
Siemens · SCALANCE XC206-2SFP G EECversion=0 <V4.6
Siemens · SCALANCE XB205-3 (ST, E/IP)version=0 <V4.6
Siemens · SCALANCE XP208G EECversion=0 <V4.6
Siemens · SCALANCE MUM856-1 (CN)version=0 <V8.1
Siemens · SCALANCE XC216EECversion=0 <V4.6
Siemens · SCALANCE XC216-4C Gversion=0 <V4.6
Siemens · SCALANCE XB213-3 (SC, PN)version=0 <V4.6
Siemens · SCALANCE XB205-3LD (SC, E/IP)version=0 <V4.6
Siemens · SCALANCE M812-1 ADSL Routerversion=0 <V8.1
Siemens · SIPLUS NET SCALANCE XC206-2version=0 <V4.6
Siemens · SCALANCE XC216-3G PoEversion=0 <V4.6
Siemens · SCALANCE S615 EEC LAN Routerversion=0 <V8.1
Siemens · SCALANCE XC206-2 (SC)version=0 <V4.6
Siemens · SCALANCE XC208EECversion=0 <V4.6
Siemens · SCALANCE XP208version=0 <V4.6
Siemens · SCALANCE M826-2 SHDSL-Routerversion=0 <V8.1
Siemens · SCALANCE M816-1 ADSL Routerversion=0 <V8.1
Siemens · SCALANCE M876-3 (ROK)version=0 <V8.1
Siemens · SCALANCE XP208 (Ethernet/IP)version=0 <V4.6
Siemens · SCALANCE M876-3version=0 <V8.1
Siemens · SCALANCE XC206-2G PoE (54 V DC)version=0 <V4.6
Siemens · SIPLUS NET SCALANCE XC216-4Cversion=0 <V4.6
Siemens · SCALANCE XC216-4C G EECversion=0 <V4.6
Siemens · SCALANCE XB205-3 (SC, PN)version=0 <V4.6
Siemens · SCALANCE XB206-2 SCversion=0 <V4.6
Siemens · SCALANCE XB206-2 (ST/BFOC)version=0 <V4.6
Siemens · SCALANCE XC224-4C Gversion=0 <V4.6
Siemens · SCALANCE XB216 (PN)version=0 <V4.6
Siemens · SCALANCE XP208PoE EECversion=0 <V4.6
Siemens · SCALANCE XP208G PoE EECversion=0 <V4.6
Siemens · SCALANCE MUM853-1 (A1)version=0 <V8.1
Siemens · SCALANCE XB208 (E/IP)version=0 <V4.6
Siemens · SCALANCE XP216G PoE EECversion=0 <V4.6
Siemens · SCALANCE M804PBversion=0 <V8.1
Siemens · SCALANCE XB206-2 LDversion=0 <V4.6
Siemens · SCALANCE XR328-4C WG (28xGE, AC 230V)version=0 <V4.6
Siemens · SCALANCE XF204version=0 <V4.6
Siemens · SCALANCE XR326-2C PoE WGversion=0 <V4.6
Siemens · SCALANCE XC208version=0 <V4.6
Siemens · SCALANCE XB206-2 STversion=0 <V4.6
Siemens · SCALANCE XC224version=0 <V4.6
Siemens · SCALANCE XC224-4C G EECversion=0 <V4.6
Siemens · SCALANCE M876-4version=0 <V8.1
Siemens · SCALANCE XP216POE EECversion=0 <V4.6
Siemens · SCALANCE XF204-2BA DNAversion=0 <V4.6
Siemens · SCALANCE XC206-2SFP EECversion=0 <V4.6
Siemens · SCALANCE XP216EECversion=0 <V4.6
Siemens · SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)version=0 <V4.6
Siemens · SCALANCE M876-4 (NAM)version=0 <V8.1
Siemens · SCALANCE MUM853-1 (EU)version=0 <V8.1
Siemens · SCALANCE XC206-2G PoEversion=0 <V4.6
Siemens · SCALANCE XB208 (PN)version=0 <V4.6
Siemens · SCALANCE XB213-3 (SC, E/IP)version=0 <V4.6
Siemens · SCALANCE XB216 (E/IP)version=0 <V4.6
Siemens · SCALANCE XC208G PoE (54 V DC)version=0 <V4.6
Siemens · SCALANCE XP208Gversion=0 <V4.6
Siemens · SCALANCE XB205-3LD (SC, PN)version=0 <V4.6
Siemens · SIPLUS NET SCALANCE XC206-2SFPversion=0 <V4.6
Siemens · SCALANCE XP216G EECversion=0 <V4.6
Siemens · SCALANCE XB213-3 (ST, PN)version=0 <V4.6
Siemens · SCALANCE S615 LAN-Routerversion=0 <V8.1
Siemens · SCALANCE M876-4 (EU)version=0 <V8.1
Siemens · SCALANCE XB213-3 (ST, E/IP)version=0 <V4.6
Siemens · SCALANCE M874-3 3G-Router (CN)version=0 <V8.1
Siemens · SCALANCE XC216-3G PoE (54 V DC)version=0 <V4.6
Siemens · SCALANCE XC206-2G PoE EEC (54 V DC)version=0 <V4.6
Siemens · SCALANCE M874-2version=0 <V8.1

Published CVSS scores

5.1Siemens AGCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
2.7Siemens AGCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesadmin
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-400Uncontrolled Resource Consumption
T1499Endpoint Denial of Service

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo