Authenticated outlet control via trusted administrator UID
Published May 28, 2024 · Updated Feb 13, 2025
Incorrect access control in ATEN PE6208 2.3.228 and 2.4.232 allows remote authenticated users to switch any outlet via HTTP POST requests. The outlet_access/connections.cgi handler accepts a valid unprivileged SID and trusts UID=8 as the administrator while processing outcont40X power-state parameters. Any low-privilege web account can therefore energize or de-energize all connected equipment, and switching an outlet off interrupts the powered service.
Summary
What happened
Incorrect access control in ATEN PE6208 2.3.228 and 2.4.232 allows remote authenticated users to switch any outlet via HTTP POST requests. The outlet_access/connections.cgi handler accepts a valid unprivileged SID and trusts UID=8 as the administrator while processing outcont40X power-state parameters. Any low-privilege web account can therefore energize or de-energize all connected equipment, and switching an outlet off interrupts the powered service.
The record
- CVE
- CVE-2023-43847
- Published
- May 28, 2024
- Updated
- Feb 13, 2025
- Vendor
- ATEN
- Product
- PE6208 Firmware
- Classifications
- CWE-284, T1529
- Attack vector
- network
- Privileges
- authenticated
Timeline
How it unfolded
- May 28, 2024CVE publishedPublication date reported by the CVE source.
- Feb 13, 2025Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=2.3.228
- Affected versionversion=2.4.232
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Public exploit references
- PE6208 outlet-control HTTP POST proof of conceptfunctional · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.
Technologies
Your stack
See the directory against your own environment.
Your stack
Check the software in your environment
Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.