Root command execution via unsanitized update filename
Published Aug 22, 2023 · Updated Jan 16, 2025
Command injection in Trane XL824, XL850, XL1050, and Pivot thermostats allows physically proximate attackers to execute commands as root. The SoftwareUpgrade.rb service passes an attacker-controlled USB update filename to a shell untar command after a permissive partial regex match, without neutralizing shell metacharacters. Inserting a USB drive containing a crafted, higher-build filename triggers automatic processing and grants complete root control of the thermostat.
Summary
What happened
Command injection in Trane XL824, XL850, XL1050, and Pivot thermostats allows physically proximate attackers to execute commands as root. The SoftwareUpgrade.rb service passes an attacker-controlled USB update filename to a shell untar command after a permissive partial regex match, without neutralizing shell metacharacters. Inserting a USB drive containing a crafted, higher-build filename triggers automatic processing and grants complete root control of the thermostat.
The record
- CVE
- CVE-2023-4212
- Published
- Aug 22, 2023
- Updated
- Jan 16, 2025
- Vendor
- Trane Technologies
- Product
- ComfortLink II XL1050 Thermostat
- Classifications
- CWE-77, CWE-74, T1059.004
- Attack vector
- physical
- Privileges
- unauthenticated
Timeline
How it unfolded
- Aug 22, 2023CVE publishedPublication date reported by the CVE source.
- Jan 16, 2025Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=0 <=5.9.8
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- Finding a command injection vulnerability in my smart thermostat (CVE-2023-4212)functional · demonstrated