CVE-2023-25550Network attack vector

Authenticated code execution via crafted hostname

Published Apr 18, 2023 · Updated Feb 12, 2025

Code injection in Schneider Electric EcoStruxure IT Data Center Expert 7.9.2 and earlier allows remote authenticated users to execute code. The network-settings hostname parameter accepts crafted syntax and generates executable code from the untrusted value. High-privileged application access is required, and successful exploitation permits complete compromise of the server process and its data.

CVSS severity7.2
High
EPSS probability1.18%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Code injection in Schneider Electric EcoStruxure IT Data Center Expert 7.9.2 and earlier allows remote authenticated users to execute code. The network-settings hostname parameter accepts crafted syntax and generates executable code from the untrusted value. High-privileged application access is required, and successful exploitation permits complete compromise of the server process and its data.

The record

CVE
CVE-2023-25550
Published
Apr 18, 2023
Updated
Feb 12, 2025
Vendor
Distributed Data Systems
Product
EcoStruxure IT Data Center Expert
Classifications
CWE-94, T1190
Attack vector
network
Privileges
admin

Timeline

How it unfolded

  1. Apr 18, 2023CVE publishedPublication date reported by the CVE source.
  2. Feb 12, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=All <=V7.9.2

What conditions does exploitation require?

Attack vectornetwork
Required privilegesadmin

What is affected?

Distributed Data Systems · EcoStruxure IT Data Center Expertversion=All <=V7.9.2

Published CVSS scores

7.2Schneider Electric SECVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
9.8NIST NVDCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesadmin
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-94Improper Control of Generation of Code ('Code Injection')
T1190Exploit Public-Facing Application

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo