CVE-2023-24504

Update redirection via undisclosed server validation

Published Apr 17, 2023 · Updated Feb 6, 2025

Update-server redirection in Electra Air Central AC Unit Firmware allows adjacent attackers to select an unauthorized update server. The published advisory does not identify the firmware component or explain which update-server validation or network operation accepts attacker-controlled input. Exploitation requires adjacent-network access and can redirect the unit's update connection; whether a malicious server can install firmware or cause other effects is undisclosed.

CVSS severity7.5
High
EPSS probability0.27%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Update-server redirection in Electra Air Central AC Unit Firmware allows adjacent attackers to select an unauthorized update server. The published advisory does not identify the firmware component or explain which update-server validation or network operation accepts attacker-controlled input. Exploitation requires adjacent-network access and can redirect the unit's update connection; whether a malicious server can install firmware or cause other effects is undisclosed.

The record

CVE
CVE-2023-24504
Published
Apr 17, 2023
Updated
Feb 6, 2025
Vendor
Electra Air
Product
Central AC Unit Firmware
Classifications
Unavailable
Attack vector
adjacent
Privileges
unauthenticated

Timeline

How it unfolded

  1. Apr 17, 2023CVE publishedPublication date reported by the CVE source.
  2. Feb 6, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=Update to the latest version <V7 & V8*

What conditions does exploitation require?

Attack vectoradjacent
Required privilegesunauthenticated

What is affected?

Electra Air · Central AC Unit Firmwareversion=Update to the latest version <V7 & V8*

Published CVSS scores

7.5Israel National Cyber DirectorateCVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectoradjacent
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

No sourced classifications are available.

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo