CVE-2023-1144Network attack vector

Authenticated privilege escalation via Device-Gateway authorization bypass

Published Mar 27, 2023 · Updated Jan 16, 2025

Improper access control in Delta Electronics InfraSuite Device Master before 1.0.5 allows remote authenticated users to escalate privileges. The Device-Gateway service on TCP port 3100 grants access to resources normally restricted from the user's privilege level because it fails to enforce authorization. Network access and low-privileged credentials are required; successful exploitation raises privileges within the application.

CVSS severity8.8
High
EPSS probability0.65%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Improper access control in Delta Electronics InfraSuite Device Master before 1.0.5 allows remote authenticated users to escalate privileges. The Device-Gateway service on TCP port 3100 grants access to resources normally restricted from the user's privilege level because it fails to enforce authorization. Network access and low-privileged credentials are required; successful exploitation raises privileges within the application.

The record

CVE
CVE-2023-1144
Published
Mar 27, 2023
Updated
Jan 16, 2025
Vendor
Delta Electronics, Inc.
Product
InfraSuite Device Master
Classifications
CWE-284, T1068
Attack vector
network
Privileges
authenticated

Timeline

How it unfolded

  1. Mar 27, 2023CVE publishedPublication date reported by the CVE source.
  2. Jan 16, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <1.0.5

What conditions does exploitation require?

Attack vectornetwork
Required privilegesauthenticated

What is affected?

Delta Electronics, Inc. · InfraSuite Device Masterversion=0 <1.0.5

Published CVSS scores

8.8ICS-CERTCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 9, 2026Sep 15, 2026
Latest reporting daySep 15, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-284Improper Access Control
T1068Exploitation for Privilege Escalation

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo