Control-panel access via reused IP authorization
Published Feb 8, 2023 · Updated Jul 23, 2025
Improper access control in Bosch B420 Ethernet Communication Module all versions allows remote attackers to access its control panel. The module authorizes requests by source IP, so an attacker on the same network inherits a valid user's authorization after that user signs in. Reachability requires adjacent network access and a prior legitimate login from the relevant IP; Bosch states that the module cannot directly access the alarm-panel bus.
Summary
What happened
Improper access control in Bosch B420 Ethernet Communication Module all versions allows remote attackers to access its control panel. The module authorizes requests by source IP, so an attacker on the same network inherits a valid user's authorization after that user signs in. Reachability requires adjacent network access and a prior legitimate login from the relevant IP; Bosch states that the module cannot directly access the alarm-panel bus.
The record
- CVE
- CVE-2022-47648
- Published
- Feb 8, 2023
- Updated
- Jul 23, 2025
- Vendor
- Bosch Security Systems B.V.
- Product
- B420 Ethernet Communication Module
- Classifications
- CWE-284, T1190
- Attack vector
- adjacent
- Privileges
- unauthenticated
Timeline
How it unfolded
- Feb 8, 2023CVE publishedPublication date reported by the CVE source.
- Jul 23, 2025Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=All Versions
What conditions does exploitation require?
What is affected?
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Public exploit references
No public exploit references are available in this record.
Labels summarize the accepted research assessment. They do not indicate a test against your environment.