CVE-2022-41772Network attack vector

Administrator code execution via unchecked ZIP paths

Published Oct 31, 2022 · Updated Apr 16, 2025

Path traversal in Delta Electronics InfraSuite Device Master 00.00.01a and earlier allows remote attackers to execute arbitrary code. The CheckLoadingStartupConfig function uses an attacker-supplied ZIP entry path in file operations without restricting it to the extraction directory. No authentication or user interaction is required, and successful exploitation executes code with administrator privileges.

CVSS severity9.8
Critical
EPSS probability24.95%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Path traversal in Delta Electronics InfraSuite Device Master 00.00.01a and earlier allows remote attackers to execute arbitrary code. The CheckLoadingStartupConfig function uses an attacker-supplied ZIP entry path in file operations without restricting it to the extraction directory. No authentication or user interaction is required, and successful exploitation executes code with administrator privileges.

The record

CVE
CVE-2022-41772
Published
Oct 31, 2022
Updated
Apr 16, 2025
Vendor
Delta Electronics, Inc.
Product
InfraSuite Device Master
Classifications
CWE-22, T1210
Attack vector
network
Privileges
unauthenticated

Timeline

How it unfolded

  1. Oct 31, 2022CVE publishedPublication date reported by the CVE source.
  2. Apr 16, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <=00.00.01a

What conditions does exploitation require?

Attack vectornetwork
Required privilegesunauthenticated

What is affected?

Delta Electronics, Inc. · InfraSuite Device Masterversion=0 <=00.00.01a

Published CVSS scores

9.8ICS-CERTCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-22Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
T1210Exploitation of Remote Services

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo