Firmware authenticity flaws in Siemens LOGO! 8 BM before 8.3 allow physically proximate attackers to flash manipulated firmware. The firmware update path accepts packages without authenticating them and checks unencrypted firmware integrity only through a non-cryptographic method. Physical access to the update mechanism is required, and exploitation installs attacker-modified firmware, compromising device integrity and availability.

CVSS severity6.1
Medium
EPSS probability0.28%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Firmware authenticity flaws in Siemens LOGO! 8 BM before 8.3 allow physically proximate attackers to flash manipulated firmware. The firmware update path accepts packages without authenticating them and checks unencrypted firmware integrity only through a non-cryptographic method. Physical access to the update mechanism is required, and exploitation installs attacker-modified firmware, compromising device integrity and availability.

The record

CVE
CVE-2022-36360
Published
Oct 11, 2022
Updated
Aug 3, 2024
Vendor
Siemens
Product
LOGO! 8 BM
Classifications
CWE-345, CWE-354, T1542.001
Attack vector
physical
Privileges
unauthenticated

Timeline

How it unfolded

  1. Oct 11, 2022CVE publishedPublication date reported by the CVE source.
  2. Aug 3, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=All versions < V8.3

What conditions does exploitation require?

Attack vectorphysical
Required privilegesunauthenticated

What is affected?

Siemens · LOGO! 8 BMversion=All versions < V8.3

Published CVSS scores

6.1Siemens ProductCERTCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
7.5NIST National Vulnerability DatabaseCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorphysical
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-345Insufficient Verification of Data Authenticity
CWE-354Improper Validation of Integrity Check Value
T1542.001System Firmware

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo