CVE-2022-32748

Credential disclosure via improper certificate validation

Published Jan 30, 2023 · Updated Feb 5, 2025

Improper certificate validation in EcoStruxure Cybersecurity Admin Expert before 2.2 allows man-in-the-middle attackers to expose credentials. Schneider Electric has not disclosed the affected connection path or the certificate check that improperly trusts a peer. Exploitation requires an adjacent network position and user interaction during device configuration; leaked credentials permit access to CAE and other managed devices.

CVSS severity7.9
High
EPSS probability0.14%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Improper certificate validation in EcoStruxure Cybersecurity Admin Expert before 2.2 allows man-in-the-middle attackers to expose credentials. Schneider Electric has not disclosed the affected connection path or the certificate check that improperly trusts a peer. Exploitation requires an adjacent network position and user interaction during device configuration; leaked credentials permit access to CAE and other managed devices.

The record

CVE
CVE-2022-32748
Published
Jan 30, 2023
Updated
Feb 5, 2025
Vendor
Distributed Data Systems
Product
EcoStruxure Cybersecurity Admin Expert
Classifications
CWE-295, T1557
Attack vector
adjacent
Privileges
unauthenticated

Timeline

How it unfolded

  1. Jan 30, 2023CVE publishedPublication date reported by the CVE source.
  2. Feb 5, 2025Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=All <2.2

What conditions does exploitation require?

Attack vectoradjacent
Required privilegesunauthenticated

What is affected?

Distributed Data Systems · EcoStruxure Cybersecurity Admin Expertversion=All <2.2

Published CVSS scores

7.9Schneider ElectricCVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectoradjacent
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-295Improper Certificate Validation
T1557Adversary-in-the-Middle

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo