CVE-2022-32257Network attack vector

Unauthenticated resource access via unprotected web endpoints

Published Mar 12, 2024 · Updated Aug 3, 2024

Improper access control in Siemens SINEMA Remote Connect Server before 3.2 allows remote attackers to access resources through web endpoints. The web service exposes some endpoints without enforcing required authorization checks; Siemens has not identified the endpoints or disclosed the faulty code path. No authentication or user interaction is required, and the documented consequence extends from unauthorized resource access to code execution.

CVSS severity9.3
Critical
EPSS probability0.84%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Improper access control in Siemens SINEMA Remote Connect Server before 3.2 allows remote attackers to access resources through web endpoints. The web service exposes some endpoints without enforcing required authorization checks; Siemens has not identified the endpoints or disclosed the faulty code path. No authentication or user interaction is required, and the documented consequence extends from unauthorized resource access to code execution.

The record

CVE
CVE-2022-32257
Published
Mar 12, 2024
Updated
Aug 3, 2024
Vendor
Siemens
Product
SINEMA Remote Connect Server
Classifications
CWE-284, T1190
Attack vector
network
Privileges
unauthenticated

Timeline

How it unfolded

  1. Mar 12, 2024CVE publishedPublication date reported by the CVE source.
  2. Aug 3, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <3.2
  2. Affected versionversion=0 <V3.2

What conditions does exploitation require?

Attack vectornetwork
Required privilegesunauthenticated

What is affected?

Siemens · SINEMA Remote Connect Serverversion=0 <3.2; version=0 <V3.2

Published CVSS scores

9.8Siemens AGCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.3Siemens ProductCERTCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-284Improper Access Control
T1190Exploit Public-Facing Application

Public exploit references

No public exploit references are available in this record.