Administrative settings compromise via missing authorization
Published Oct 11, 2022 · Updated Aug 3, 2024
Missing authorization in Nokia AirFrame BMC Web GUI before 4.13.00 allows remote authenticated users to read data and alter settings. The /#settings/* pages and /api/settings/* endpoints fail to enforce server-side permission checks, so an Operator can submit administrative configuration changes hidden by client-side controls. Access requires a low-privileged Operator account; successful requests expose sensitive settings, change system configuration, and can interrupt service.
Summary
What happened
Missing authorization in Nokia AirFrame BMC Web GUI before 4.13.00 allows remote authenticated users to read data and alter settings. The /#settings/* pages and /api/settings/* endpoints fail to enforce server-side permission checks, so an Operator can submit administrative configuration changes hidden by client-side controls. Access requires a low-privileged Operator account; successful requests expose sensitive settings, change system configuration, and can interrupt service.
The record
- CVE
- CVE-2022-28866
- Published
- Oct 11, 2022
- Updated
- Aug 3, 2024
- Vendor
- Unknown vendor
- Product
- Unknown product
- Classifications
- CWE-862, T1068
- Attack vector
- network
- Privileges
- authenticated
Timeline
How it unfolded
- Oct 11, 2022CVE publishedPublication date reported by the CVE source.
- Aug 3, 2024Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
What conditions does exploitation require?
What is affected?
Affected products and versions are unavailable in this record.
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Public exploit references
- TIM Nokia AirFrame BMC settings authorization bypass PoCproof of concept · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.
Technologies
Your stack
See the directory against your own environment.
Your stack
Check the software in your environment
Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.