CVE-2022-25753Network attack vector

Authenticated code execution via CLI buffer overflow

Published Apr 12, 2022 · Updated Aug 3, 2024

Stack-based buffer overflow in Siemens SCALANCE X-300 firmware before 4.1.4 allows remote authenticated users to execute arbitrary code. The device CLI handles arguments such as IP addresses without adequate bounds enforcement, allowing data to overrun a stack buffer. Reachability requires valid credentials and network access to the management CLI; successful exploitation grants code execution on the switch.

CVSS severity7.5
High
EPSS probability1.70%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Stack-based buffer overflow in Siemens SCALANCE X-300 firmware before 4.1.4 allows remote authenticated users to execute arbitrary code. The device CLI handles arguments such as IP addresses without adequate bounds enforcement, allowing data to overrun a stack buffer. Reachability requires valid credentials and network access to the management CLI; successful exploitation grants code execution on the switch.

The record

CVE
CVE-2022-25753
Published
Apr 12, 2022
Updated
Aug 3, 2024
Vendor
Siemens
Product
SCALANCE X307-2 EEC (2x 230V)
Classifications
CWE-787, CWE-121, T1210
Attack vector
network
Privileges
authenticated

Timeline

How it unfolded

  1. Apr 12, 2022CVE publishedPublication date reported by the CVE source.
  2. Aug 3, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=All versions < V4.1.4

What conditions does exploitation require?

Attack vectornetwork
Required privilegesauthenticated

What is affected?

Siemens · SCALANCE X307-2 EEC (2x 230V)version=All versions < V4.1.4
Siemens · SCALANCE X308-2Mversion=All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE (230V, ports on front)version=All versions < V4.1.4
Siemens · SCALANCE XR324-12M (24V, ports on front)version=All versions < V4.1.4
Siemens · SCALANCE X307-3LDversion=All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (24V)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE (24V, ports on rear)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on front)version=All versions < V4.1.4
Siemens · SCALANCE X320-1 FEversion=All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (2x 230V, coated)version=All versions < V4.1.4
Siemens · SCALANCE XR324-12M (230V, ports on rear)version=All versions < V4.1.4
Siemens · SCALANCE X310FEversion=All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (2x 24V)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (24V, ports on front)version=All versions < V4.1.4
Siemens · SCALANCE XR324-12M (24V, ports on rear)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE (24V, ports on front)version=All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (2x 24V)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)version=All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (24V, coated)version=All versions < V4.1.4
Siemens · SCALANCE X310version=All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (230V)version=All versions < V4.1.4
Siemens · SCALANCE X308-2version=All versions < V4.1.4
Siemens · SCALANCE XR324-12M TS (24V)version=All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (2x 24V, coated)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE (230V, ports on rear)version=All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (230V, coated)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (24V, ports on rear)version=All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (24V, coated)version=All versions < V4.1.4
Siemens · SCALANCE X307-3version=All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (24V)version=All versions < V4.1.4
Siemens · SCALANCE X308-2LH+version=All versions < V4.1.4
Siemens · SCALANCE X308-2M PoEversion=All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (230V, coated)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on rear)version=All versions < V4.1.4
Siemens · SCALANCE X302-7 EEC (2x 230V)version=All versions < V4.1.4
Siemens · SCALANCE X308-2M TSversion=All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (230V)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)version=All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (2x 230V, coated)version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)version=All versions < V4.1.4
Siemens · SCALANCE X306-1LD FEversion=All versions < V4.1.4
Siemens · SCALANCE XR324-12M (230V, ports on front)version=All versions < V4.1.4
Siemens · SCALANCE X304-2FEversion=All versions < V4.1.4
Siemens · SCALANCE X308-2LDversion=All versions < V4.1.4
Siemens · SCALANCE X307-2 EEC (2x 24V, coated)version=All versions < V4.1.4
Siemens · SCALANCE X320-1-2LD FEversion=All versions < V4.1.4
Siemens · SCALANCE X408-2version=All versions < V4.1.4
Siemens · SCALANCE XR324-4M PoE TS (24V, ports on front)version=All versions < V4.1.4
Siemens · SIPLUS NET SCALANCE X308-2version=All versions < V4.1.4

Published CVSS scores

6.5NIST NVDAV:N/AC:L/Au:S/C:P/I:P/A:P
7.5Siemens ProductCERTCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8NIST NVDCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectornetwork
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-787Out-of-bounds Write
CWE-121Stack-based Buffer Overflow
T1210Exploitation of Remote Services

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo