Communication interruption via unchecked file length subtraction
Published May 18, 2022 · Updated Aug 3, 2024
Improper input validation in Mitsubishi Electric MELSEC iQ-F CPU firmware allows remote attackers to interrupt PLC communications. When closing a crafted transferred file, the controller subtracts an unvalidated header size from the total file size and uses the resulting body length for checksum processing. Unauthenticated network access is sufficient; exploitation disables the targeted protocol port while PLC program execution continues.
Summary
What happened
Improper input validation in Mitsubishi Electric MELSEC iQ-F CPU firmware allows remote attackers to interrupt PLC communications. When closing a crafted transferred file, the controller subtracts an unvalidated header size from the total file size and uses the resulting body length for checksum processing. Unauthenticated network access is sufficient; exploitation disables the targeted protocol port while PLC program execution continues.
The record
- CVE
- CVE-2022-25162
- Published
- May 18, 2022
- Updated
- Aug 3, 2024
- Vendor
- Unknown vendor
- Product
- Unknown product
- Classifications
- CWE-20, T0814
- Attack vector
- network
- Privileges
- unauthenticated
Timeline
How it unfolded
- May 18, 2022CVE publishedPublication date reported by the CVE source.
- Aug 3, 2024Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
What conditions does exploitation require?
What is affected?
Affected products and versions are unavailable in this record.
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Public exploit references
- Hacking Mitsubishi PLC Without Access to Firmware proof of conceptproof of concept · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.
Technologies
Your stack
See the directory against your own environment.
Your stack
Check the software in your environment
Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.