CVE-2022-23448

Local privilege escalation via insecure filesystem permissions

Published Apr 12, 2022 · Updated Aug 3, 2024

Incorrect permissions in Siemens SIMATIC Energy Manager Basic and PRO before 7.3 Update 1 allow local users to execute elevated code. The applications grant overly broad permissions to unspecified critical directories and files used by privileged application processes. Exploitation requires local low-privileged access and can execute code as Administrator or NT AUTHORITY/SYSTEM.

CVSS severity7.8
High
EPSS probability0.25%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Incorrect permissions in Siemens SIMATIC Energy Manager Basic and PRO before 7.3 Update 1 allow local users to execute elevated code. The applications grant overly broad permissions to unspecified critical directories and files used by privileged application processes. Exploitation requires local low-privileged access and can execute code as Administrator or NT AUTHORITY/SYSTEM.

The record

CVE
CVE-2022-23448
Published
Apr 12, 2022
Updated
Aug 3, 2024
Vendor
Siemens
Product
SIMATIC Energy Manager PRO
Classifications
CWE-732, T1574
Attack vector
local
Privileges
authenticated

Timeline

How it unfolded

  1. Apr 12, 2022CVE publishedPublication date reported by the CVE source.
  2. Aug 3, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=All versions < V7.3 Update 1

What conditions does exploitation require?

Attack vectorlocal
Required privilegesauthenticated

What is affected?

Siemens · SIMATIC Energy Manager PROversion=All versions < V7.3 Update 1
Siemens · SIMATIC Energy Manager Basicversion=All versions < V7.3 Update 1

Published CVSS scores

7.2NIST NVDAV:L/AC:L/Au:N/C:C/I:C/A:C
7.8NIST NVDCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 9, 2026Sep 15, 2026
Latest reporting daySep 15, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorlocal
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-732Incorrect Permission Assignment for Critical Resource
T1574Hijack Execution Flow

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo