Unauthenticated OPC UA access via skipped password verification
Published Jul 11, 2022 · Updated Sep 16, 2024
Authentication bypass in affected Lenze c520, c550, and c750 firmware allows remote attackers unauthorized OPC UA access. The firmware interface to the embedded OPC UA server skips password verification on a client's second user/password login. The flaw is reachable only after an earlier login and when user management, the OPC UA server, and symbol-based data transfer are enabled.
Summary
What happened
Authentication bypass in affected Lenze c520, c550, and c750 firmware allows remote attackers unauthorized OPC UA access. The firmware interface to the embedded OPC UA server skips password verification on a client's second user/password login. The flaw is reachable only after an earlier login and when user management, the OPC UA server, and symbol-based data transfer are enabled.
The record
- CVE
- CVE-2022-2302
- Published
- Jul 11, 2022
- Updated
- Sep 16, 2024
- Vendor
- Lenze
- Product
- c520 controller
- Classifications
- CWE-287, CWE-304, T0819
- Attack vector
- network
- Privileges
- unauthenticated
Timeline
How it unfolded
- Jul 11, 2022CVE publishedPublication date reported by the CVE source.
- Sep 16, 2024Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=V01.07.00.2757 <V01.08.01.3021
What conditions does exploitation require?
What is affected?
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
No public exploit references are available in this record.