CVE-2021-38442

Code execution via unchecked project data copies

Published Oct 18, 2021 · Updated Sep 16, 2024

Memory corruption in FATEK Automation WinProladder 3.30 and earlier allows attackers to execute code via crafted project data. Its PDW and PLC-configuration parsers fail to validate attacker-controlled lengths before copying data into stack buffers, causing memory corruption. Execution requires a user to open a malicious file, visit a page that delivers one, or access a compromised PLC device or network; code runs in the current process.

CVSS severity7.8
High
EPSS probability0.97%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Memory corruption in FATEK Automation WinProladder 3.30 and earlier allows attackers to execute code via crafted project data. Its PDW and PLC-configuration parsers fail to validate attacker-controlled lengths before copying data into stack buffers, causing memory corruption. Execution requires a user to open a malicious file, visit a page that delivers one, or access a compromised PLC device or network; code runs in the current process.

The record

CVE
CVE-2021-38442
Published
Oct 18, 2021
Updated
Sep 16, 2024
Vendor
FATEK Automation Corporation
Product
WinProladder
Classifications
CWE-787, CWE-119, T1203, T1204.002
Attack vector
local
Privileges
unauthenticated

Timeline

How it unfolded

  1. Oct 18, 2021CVE publishedPublication date reported by the CVE source.
  2. Sep 16, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=All <=3.30

What conditions does exploitation require?

Attack vectorlocal
Required privilegesunauthenticated

What is affected?

FATEK Automation Corporation · WinProladderversion=All <=3.30

Published CVSS scores

7.8ICS-CERTCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
8.8Zero Day Initiative ZDI-21-1172CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorlocal
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-787Out-of-bounds Write
CWE-119Improper Restriction of Operations within the Bounds of a Memory Buffer
T1203Exploitation for Client Execution
T1204.002Malicious File

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo