CVE-2021-25675

Local application crash via crafted project file

Published Mar 15, 2021 · Updated Aug 3, 2024

Divide-by-zero in Siemens SIMATIC S7-PLCSIM V5.4 allows local users to crash the application through a crafted project file. The affected file-opening path performs a division operation with a zero divisor; Siemens has not disclosed the responsible function or field. The attacker requires local access and a crafted project file; successful exploitation stops simulation until the application is restarted.

CVSS severity5.5
Medium
EPSS probability0.22%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Divide-by-zero in Siemens SIMATIC S7-PLCSIM V5.4 allows local users to crash the application through a crafted project file. The affected file-opening path performs a division operation with a zero divisor; Siemens has not disclosed the responsible function or field. The attacker requires local access and a crafted project file; successful exploitation stops simulation until the application is restarted.

The record

CVE
CVE-2021-25675
Published
Mar 15, 2021
Updated
Aug 3, 2024
Vendor
Siemens
Product
SIMATIC S7-PLCSIM
Classifications
CWE-369, T1499.004
Attack vector
local
Privileges
authenticated

Timeline

How it unfolded

  1. Mar 15, 2021CVE publishedPublication date reported by the CVE source.
  2. Aug 3, 2024Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=All versions

What conditions does exploitation require?

Attack vectorlocal
Required privilegesauthenticated

What is affected?

Siemens · SIMATIC S7-PLCSIMversion=All versions

Published CVSS scores

2.1NIST NVDAV:L/AC:L/Au:N/C:N/I:N/A:P
5.5NIST NVDCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 9, 2026Sep 15, 2026
Latest reporting daySep 15, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectorlocal
Privilegesauthenticated
Known exploitationUnconfirmed
Public exploitUnconfirmed

Weakness, pattern, technique

CWE-369Divide By Zero
T1499.004Endpoint Denial of Service: Application or System Exploitation

Public exploit references

No public exploit references are available in this record.

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo