Controller code injection via replaced compiler DLL
Published Mar 23, 2020 · Updated Aug 4, 2024
Reflective DLL injection in Schneider Electric engineering software and Modicon firmware allows attackers to transfer malicious code to PLCs. A replacement asmArm.dll hooks MyAsmArmStream during project compilation and injects attacker-supplied ARM bytecode into the controller program. Exploitation requires modification of the engineering workstation and user interaction to recompile and transfer the project, after which the code executes on the PLC.
Summary
What happened
Reflective DLL injection in Schneider Electric engineering software and Modicon firmware allows attackers to transfer malicious code to PLCs. A replacement asmArm.dll hooks MyAsmArmStream during project compilation and injects attacker-supplied ARM bytecode into the controller program. Exploitation requires modification of the engineering workstation and user interaction to recompile and transfer the project, after which the code executes on the PLC.
The record
- CVE
- CVE-2020-7475
- Published
- Mar 23, 2020
- Updated
- Aug 4, 2024
- Vendor
- Unknown vendor
- Product
- Unknown product
- Classifications
- CWE-74, T0843
- Attack vector
- network
- Privileges
- unauthenticated
Timeline
How it unfolded
- Mar 23, 2020CVE publishedPublication date reported by the CVE source.
- Aug 4, 2024Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
What conditions does exploitation require?
What is affected?
Affected products and versions are unavailable in this record.
Published CVSS scores
CVSS describes severity. EPSS estimates exploitation probability.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- Applying a Stuxnet Type Attack to a Modicon PLCfunctional · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.