CVE-2020-26145Public exploit

Packet injection via plaintext broadcast fragments

Published May 11, 2021 · Updated Apr 14, 2026

Improper input validation in Siemens SCALANCE W-700 devices before 1.2.0 allows physically proximate attackers to inject network packets. The Wi-Fi receive path accepts a plaintext second or later broadcast fragment and processes it as a complete unfragmented frame. The attacker must be within Wi-Fi range; no authentication or user interaction is required, and injected traffic can bypass protected-network encryption.

CVSS severity6.5
Medium
EPSS probability3.52%
Next 30 days · Sep 16, 2026
Known exploitationUnconfirmed
Based on sourced intelligence
Hinoki checkNot available
Coverage for this vulnerability

See if you're affected

Explore vulnerability checks for your environment with Hinoki.

Book a demo

Summary

What happened

Improper input validation in Siemens SCALANCE W-700 devices before 1.2.0 allows physically proximate attackers to inject network packets. The Wi-Fi receive path accepts a plaintext second or later broadcast fragment and processes it as a complete unfragmented frame. The attacker must be within Wi-Fi range; no authentication or user interaction is required, and injected traffic can bypass protected-network encryption.

The record

CVE
CVE-2020-26145
Published
May 11, 2021
Updated
Apr 14, 2026
Vendor
Siemens
Product
SCALANCE WAM766-1 (US)
Classifications
CWE-20, T1659
Attack vector
adjacent
Privileges
unauthenticated

Timeline

How it unfolded

  1. May 11, 2021CVE publishedPublication date reported by the CVE source.
  2. Apr 14, 2026Record updatedLatest update available in the CVE record.

Exploitability

Present is not the same as exploitable

Compare your product and version with the public record. A matching version still requires validation against your environment.

Is a vulnerable build present?

Compare these published version ranges with your installed build and any vendor patches.

  1. Affected versionversion=0 <V1.2.0

What conditions does exploitation require?

Attack vectoradjacent
Required privilegesunauthenticated

What is affected?

Siemens · SCALANCE WAM766-1 (US)version=0 <V1.2.0
Siemens · SCALANCE WUM766-1version=0 <V1.2.0
Siemens · SCALANCE WAM763-1version=0 <V1.2.0
Siemens · SCALANCE WAM766-1version=0 <V1.2.0
Siemens · SCALANCE WAM766-1 EECversion=0 <V1.2.0
Siemens · SCALANCE WAM766-1 EEC (US)version=0 <V1.2.0
Siemens · SCALANCE WUM766-1 (USA)version=0 <V1.2.0
Siemens · SCALANCE WUM763-1version=0 <V1.2.0

Published CVSS scores

6.5Siemens ProductCERTCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

CVSS describes severity. EPSS estimates exploitation probability.

Attacks

What attackers are doing with it

Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.

Daily unique IPsNo honeypot observations are available for this CVE in the selected window.

No observations available

Sep 10, 2026Sep 16, 2026
Latest reporting daySep 16, 2026
Latest daily unique IPsUnavailable
Prior 30-day averageUnavailable
SourceShadowserver honeypots (KEV)
Vectoradjacent
Privilegesunauthenticated
Known exploitationUnconfirmed
Public exploitPublished

Weakness, pattern, technique

CWE-20Improper Input Validation
T1659Content Injection

Public exploit references

Labels summarize the accepted research assessment. They do not indicate a test against your environment.

Technologies

Your stack

See the directory against your own environment.

Your stack

Check the software in your environment

Book a demo to see how Hinoki identifies affected software and validates exploitability in your environment.

Book a demo