Local SYSTEM execution via writable DLL path
Published Feb 9, 2021 · Updated Aug 4, 2024
Privilege escalation in Siemens DIGSI 4 before V4.94 SP1 HF 1 allows local users to execute code as SYSTEM via writable DLL search-path folders. Several directories in the Windows %PATH% are writable by normal users but searched for DLLs by DIGSI 4 or related processes. A local authenticated user can plant a malicious DLL, and execution occurs with SYSTEM privileges, enabling full confidentiality, integrity, and availability impact.
Summary
What happened
Privilege escalation in Siemens DIGSI 4 before V4.94 SP1 HF 1 allows local users to execute code as SYSTEM via writable DLL search-path folders. Several directories in the Windows %PATH% are writable by normal users but searched for DLLs by DIGSI 4 or related processes. A local authenticated user can plant a malicious DLL, and execution occurs with SYSTEM privileges, enabling full confidentiality, integrity, and availability impact.
The record
- CVE
- CVE-2020-25245
- Published
- Feb 9, 2021
- Updated
- Aug 4, 2024
- Vendor
- Siemens
- Product
- DIGSI 4
- Classifications
- CWE-276, T1574.002
- Attack vector
- local
- Privileges
- authenticated
Timeline
How it unfolded
- Feb 9, 2021CVE publishedPublication date reported by the CVE source.
- Aug 4, 2024Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
Compare these published version ranges with your installed build and any vendor patches.
- Affected versionversion=All versions < V4.94 SP1 HF 1
What conditions does exploitation require?
What is affected?
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Public exploit references
No public exploit references are available in this record.