Local system reboot via permissive driver device access
Published Dec 28, 2021 · Updated Aug 4, 2024
Improper access control in EVGA Precision XOC 6.2.7 allows local users to access hardware through its low-level drivers. WinRin0x64.sys and WinRing0.sys keep the default device security descriptor, so a nonprivileged process can open WinRing0_1_2_0 and send port-I/O controls. A demonstrated local call writes the keyboard-controller reset port and immediately reboots Windows, while the record also identifies exposure of sensitive components and data.
Summary
What happened
Improper access control in EVGA Precision XOC 6.2.7 allows local users to access hardware through its low-level drivers. WinRin0x64.sys and WinRing0.sys keep the default device security descriptor, so a nonprivileged process can open WinRing0_1_2_0 and send port-I/O controls. A demonstrated local call writes the keyboard-controller reset port and immediately reboots Windows, while the record also identifies exposure of sensitive components and data.
The record
- CVE
- CVE-2020-22057
- Published
- Dec 28, 2021
- Updated
- Aug 4, 2024
- Vendor
- Unknown vendor
- Product
- Unknown product
- Classifications
- T1529
- Attack vector
- local
- Privileges
- authenticated
Timeline
How it unfolded
- Dec 28, 2021CVE publishedPublication date reported by the CVE source.
- Aug 4, 2024Record updatedLatest update available in the CVE record.
Exploitability
Present is not the same as exploitable
Compare your product and version with the public record. A matching version still requires validation against your environment.
Is a vulnerable build present?
What conditions does exploitation require?
What is affected?
Affected products and versions are unavailable in this record.
Attacks
What attackers are doing with it
Daily unique IPs observed by Shadowserver honeypots for known exploited vulnerabilities (KEVs). Missing observations do not establish an absence of attacks.
Weakness, pattern, technique
Public exploit references
- EVGA PrecisionX OC 6.2.7 reboot proof of conceptfunctional · demonstrated
Labels summarize the accepted research assessment. They do not indicate a test against your environment.